All cardiologyASD OccluderStructural heartVSD OccluderStructural heartPDA OccluderStructural heartDelivery SystemStructural heartHisco NCCoronary interventionLaxo SCCoronary interventionLaxo SC CTOCoronary interventionOdigosCoronary interventionGioNix PFCath-lab accessoriesGioNix HDCath-lab accessoriesAngioNixCath-lab accessoriesIntronix SheathCath-lab accessoriesInflanixCath-lab accessoriesIntronix NeedleCath-lab accessoriesYnixCath-lab accessoriesManixCath-lab accessories

Spine

All spinePSSThoraco-lumbar fixationD-genThoraco-lumbar fixationTLIFLumbar interbodyPLIFLumbar interbodyACPCervicalACCCervicalSELFCervicalPCFCervicalKyphonixVertebral body & columnCCMVertebral body & column

Neurology

All neurologyRivaNIM™IONMNervENT™IONM

Company

About usFacility & qualityComplianceCareersNews & events

Resources

eIFUSurgical techniquePatients — cardiologyPatients — spinePatients — neurology Contact us
SpineCervical

Kentrospine SELF

Standalone anterior cervical cage

A zero-profile standalone cage for ACDF that combines an interbody spacer with the benefits of an anterior cervical plate.

Region: CervicalProcedure: ACDFProfile: Zero anterior profileHeights: 5–10 mm
Key highlights

SELF, feature by feature.

Anterior cervical plates and cages, a zero-profile standalone cage and a posterior cervical fixation system.

01

Zero anterior profile

Helps reduce the occurrence and severity of postoperative dysphagia.

02

Integrated plate and spacer

Preserves the anatomical profile of the spine.

03

6° lordosis

Closely approximates cervical curvature.

04

Cam-lock screws

Secure, rigid screw locking; one-step, self-tapping locking screws.

05

Minimal intervention

Small incision with less retraction.

06

Titanium alloy spacer

Fracture resistance and biocompatibility.

Overview

Kentrospine SELF standalone cage is used in traditional ACDF procedures to provide biomechanical strength for the cervical region while minimising disruption to patient anatomy.

Its design combines the function of a cervical interbody spacer with the benefits of an anterior cervical plate. Biomechanical testing has shown the stability of a standalone cage to be comparable to a traditional plate-and-spacer combination.

Technical specifications

Heights
5, 6, 7, 8, 9, 10 mm
Lordosis
6°
Screw angle
40° ± 5° cranial/caudal
Locking
Cam-lock, one step

Instructions for use

Indications, contraindications, warnings and precautions are in the IFU supplied with the product. Request the eIFU.

For healthcare professionals

Product information is intended for healthcare professionals. Availability and registration status vary by market.

Hospital, distributor or surgeon?

Request product information, instructions for use or surgical technique documents from our Cardiology, KentroSpine and Neurology teams.