All cardiologyASD OccluderStructural heartVSD OccluderStructural heartPDA OccluderStructural heartDelivery SystemStructural heartHisco NCCoronary interventionLaxo SCCoronary interventionLaxo SC CTOCoronary interventionOdigosCoronary interventionGioNix PFCath-lab accessoriesGioNix HDCath-lab accessoriesAngioNixCath-lab accessoriesIntronix SheathCath-lab accessoriesInflanixCath-lab accessoriesIntronix NeedleCath-lab accessoriesYnixCath-lab accessoriesManixCath-lab accessories

Spine

All spinePSSThoraco-lumbar fixationD-genThoraco-lumbar fixationTLIFLumbar interbodyPLIFLumbar interbodyACPCervicalACCCervicalSELFCervicalPCFCervicalKyphonixVertebral body & columnCCMVertebral body & column

Neurology

All neurologyRivaNIM™IONMNervENT™IONM

Company

About usFacility & qualityComplianceCareersNews & events

Resources

eIFUSurgical techniquePatients — cardiologyPatients — spinePatients — neurology Contact us
SpineCervical

Kentrospine ACP

Anterior cervical plate

A low-profile, pre-contoured anterior cervical plate (C2–C7) with a built-in cam-lock that gives visual and tactile assurance of the lock.

Region: Cervical (C2–C7)Approach: AnteriorPlate: 2 mm × 17 mmLock: Cam lock
Key highlights

ACP, feature by feature.

Anterior cervical plates and cages, a zero-profile standalone cage and a posterior cervical fixation system.

01

Low profile

2 mm thick, 17 mm wide.

02

Pre-contoured plate

Matches the anatomy — no intra-operative contouring.

03

Built-in cam lock

Visual and tactile assurance of the lock.

04

Colour-coded screws

Ø 4 mm and 4.35 mm, identified by function and diameter.

05

Screw angulation

15° medial angulation range, 6° lateral offset.

06

Fewer instruments

May reduce retraction and time to implant.

Overview

Kentrospine ACP is a low-profile anterior cervical plate system with a cam-lock mechanism, intended for anterior cervical fixation (C2–C7).

The pre-contoured plate matches the anatomy, avoiding the need to contour the plate during surgery. The built-in cam-locking mechanism provides visual and tactile assurance of the lock.

Technical specifications

Plate thickness
2 mm
Plate width
17 mm
Screw diameters
4 mm · 4.35 mm
Medial angulation
15° range
Lateral angulation
6° offset
Levels
C2–C7

Measurements

Kentrospine ACP — Measurements (mm)
Measurements (mm)

Instructions for use

Indications, contraindications, warnings and precautions are in the IFU supplied with the product. Request the eIFU.

For healthcare professionals

Product information is intended for healthcare professionals. Availability and registration status vary by market.

Hospital, distributor or surgeon?

Request product information, instructions for use or surgical technique documents from our Cardiology, KentroSpine and Neurology teams.